Function Control
1. F2: Up = Function 2 ON
Down = Function 2 OFF
2. F1: Up = Function 1 ON
Down = Function 1 OFF
3. Gamma: Up = 0.45
Down = 1.0
4.AGC/MGC: Up = AGC (Automatic Gain
Control)
Down = MGC (Manual Gain
Control)
When MGC is selected, the camera gain can be adjusted
using the potentiometer on the back plate.
5. FLD/FRM: Up = FLD (Field Mode)
Down = FRM (Frame Mode)
6.ASY/CYC: Up = Asynchronous Mode
Down = Cyclic Mode Shutter
7. S3 to S0: See Shutter Speed Control Switches
on the reverse side of this page.
Pulse Width Integration Mode
F1 ASY S3 S2 S1 S0 Trigger
OFF CYC 0 0 0 0 Polarity
Up Up Up Up Up Up Negative
F2 Up: SYNC signal is continuous.
F2 Down: SYNC signal is available in the two fields (Frame
mode) and in one field (Field mode) right after VINIT.
Trigger Position Reset/Restart Shutter Mode
F1 ASY S3 S2 S1 S0 Trigger
OFF CYC 0 0 0 0 Polarity
Up Down Up Up Up Down Positive
F2: not applicable.
Strobe Asynchronous Shutter Mode
F1 ASY S3 S2 S1 S0 Trigger
OFF CYC 0 0 0 0 Polarity
Down Up Down Down Down Down Negative
F2 Up: Both odd and even field pictures are obtained in
Frame mode.
Trigger Width Reset/Restart Shutter Mode
F1 ASY S3 S2 S1 S0 Trigger
OFF CYC 0 0 0 0 Polarity
Up Down Up Up Up Up Positive
F2: not applicable.
Double Pulse Integration Mode
F1 ASY S3 S2 S1 S0 Trigger
OFF CYC 0 0 0 0 Polarity
Up Up Up Up Up Down Negative
F2 Up: SYNC signal is continuous.
F2 Down: SYNC signal is available in one field right after
VINIT.
Pulse Width Asynchronous Shutter Mode
F1 ASY S3 S2 S1 S0 Trigger
OFF CYC 0 0 0 0 Polarity
Down Up Up Up Up Up Negative
F2 Up: SYNC signal is continuous.
F2 Down: SYNC signal is available in the two fields (Frame
mode) and in one field (Field mode) right after VINIT.
Comentarios a estos manuales