Page 22
Signal Handling
TM-1405GE Software
Table 3 shows which output labels carry the output signals.
Table 3. GPIO Look-Up Table Output Labels
Output label Signal Description
Q0 TTL-OUT(STROBE) Strobe output
Q1 N/A
Q2 N/A
Q3 N/A
Q4 EVINIT Trigger
Q5 N/A
Q6 EXT_VD Vertical Drive
Q7 EXT_HD Horizontal Drive
Q8 pulse_trig1 Pulse Generator 1 gets its trigger here
Q9 pulse_trig0 Pulse Generator 0 gets its trigger here
Q10 pulse_trig3 Pulse Generator 3 gets its trigger here
Q11 pulse_trig2 Pulse Generator 2 gets its trigger here
Q12 N/A
Q13 N/A
Q14 TRIG
Trigger for camera’s internal frame
grabber
Q15 RESV Reserved