4.3 TMC-73M ADJUSTMENT PROCEDURES
4.3.1 PRESET
Preset each potentiometer as follows:
PWB1
VR101 Y level = 2.5 V
VR102 SH level = 1.7 V
W101 TMC-73M...Open, TMC-63M...Short
W102 TMC-73M...Short, TMC-63M...Open
W103 TMC-73M...Open, TMC-63M...Short
W104 TMC-73M...Open, TMC-63M...Short
PWB2
W201 TMC-73M...N, TMC-63M...P
W202 Open
W203 NTSC...Open, PAL...Short
W204 NTSC...Open, PAL... Short
W205 Right side (VD)
PWB3
VR301 B-Y GAIN = 2.4 V
VR302 R-Y GAIN = 3.2 V
VR303 R cont 3200 = 3.8V
VR304 R cont 5600 = 4.0 V
VR305 B cont 3200 = 4.0 V
VR306 B cont 5600 = 3.4V
VR307 R-Y Hue = 3.5 V
VR308 B-Y Hue = 3.0 V
W301, W302 Set to 3200°K
W303 Open (AGC on)
PWB4
VR401 MGC = 2.5 V
VR402 AGC MAX = 3.0 V
VR403 AGC = 2.0 V
VR404 Vsub See Vsub voltage
VR405 IRIS level = 2.0 V
W401 Keep open. Use MGC/AGC selection
W402 NTSC... Open, PAL...Short
4.3.2 FUNCTION TEST
With above settings, the camera will output a good
picture and you can proceed to the fine tuning process.
4.3.3 WHITE BALANCE
Equipment: Color bar chart (3200°K),
Vector scope, Wave form monitor.
Set AGC and White balance selection to Manual side
(short to GND).
Set to auto-shutter off(PWB2, A/M to GND).
Use standard lens (Calibrated ) and set the iris to F=8.
For 5600°K, use blue conversion filter.
Burst level
Confirm that burst level on Vector scope is on the 75 %
line.
4.2 PREPARATION
4.2.1 BACK FOCUS ADJUSTMENT (ONLY FOR
OPTIONAL REQUIREMENT)
Subject: Resolution chart
1. Mount the manual lens (i.e. Cosmicar 25mm,
F=1.4).
2. Open the lens iris completely and set lens focal
length to minimum for the lens used (e.g. 2 ft.).
3. If image is not focused properly, set back focus as
follows.
4. Unscrew the M2x3 hex screw on the Front Panel
until the focus ring is loose.
5. Adjust the silver back focus ring until the image is
focused.
6. Repeat steps 4 and 5 if needed.
C-mount Ring
Back Focus
2 Feet
9