Switch Mode Description Action
Shutter 0 to 9 positions Shutter speed
Dial Manual mode control dial for
(MAN) manual shutter
mode
0 to 9 positions Shutter speed
Asynchronous control dial for
Reset Mode asynchronous
(ASY) shutter mode
Shutter MAN Manual shutter Camera continuously outputs
Mode mode video at 15FPS
Switch
ASY Asynchronous Camera resets on Vinit signal:
Shutter mode pin 6 of 12-pin connector
White Held down White Balance Calibrates the white balance so
Balance Reset omits that the selected object appears
Reset to be white.
IWB
RST
Released Camera maintains the last white
balance values.
White IWB Internal White Selects Internal White Balance
Balance Balance mode
Control
EWB External White Selects External White Balance
Balance mode mode. EWB preset values can be
changed via RS-232C only.
Gamma
Control
Switch
G1.0 Gamma 1.0 Selects Gamma 1.0
G0.45 Gamma 0.45 Selects Gamma 0.45
Bank Switch Bank1 Bank1 Selection Selects Bank1 camera parameter
switch set.
Bank2 Bank2 Selection Selects Bank2 camera parameter
switch set. NOTE: Bank3 and Bank4 can
be selected via RS-232C control.
Connector Type Cable Needed Cable Information
RS-232 6-pin female CBL-RS232-C9
connector
Analog 15-pin High CBL-2R-15
Density
D-sub female
connector
Digital 15-pin female 15CL-02 or
AirBorn 15CL-02-15
connector
Use the Channel Link
TM
/TTL
adapter cable if you are using a
non-Channel Link frame grabber
that needs TTL input. Use the
Direct Channel Link cable
(15CL-02-15) if you are using a
Channel Link frame grabber.
Connect a PC to the camera using
the RS-232C control cable
(CBL-RS232-C9). This cable is a
part of the communication kit
(CS-232C)
Power/Sync 12-pin Hirose 12P-02S or
male connector PD-12UU series
connector power supply
Connect a 12V DC power supply
(K25-12V or PD-12UU) using
power cable 12P-02S (also includes
external signals such as Vd, Hd,
and VINIT) or connect power
supply PD-12UUP.
Power
Analog
RS
232
SHUTTER
0
1
2
3
5
6
7
8
9
4
IWB
RST
ANALOG
IWB
EWB
G1.0 BANK1
0.45 BANK2
MAN
ASY
DIGITAL
POWER
Shutter switch mode
Shutter dial
Digital
RS-232
White balance
reset IWB RST
Please refer to the Shutter
Control Switch Diagram
Bank switch
White balance
control
Gamma control
switch
If you are using a monitor or frame
grabber that needs Red, Green,
Blue, Vertical Sync, and Horizontal
Sync, then use the RGB analog
cable (CBL-2R-15).
PULNiX
PROGRESSIVE SCAN
C
L
18.0
2X M3
116.5 (4.58)
112.5 (4.43)
67.0 (2.64)
51.0
(2.01)
7.0 (.28)
11.0
11.0
1/4"-20
2X M6
18.0
40.0
30.0
6.5
10.5
101.0
2X M3 X 6,4 DP
Comentarios a estos manuales