Page 22
Operation
TM-4000CL Series Progressive Scan Shutter Cameras
Model: TM-4000
Operation Mode: Dual Tap Output
Centered 250Ls PS
79.92 Frames/second
Master Clock: 80.000 MHz, M= 12.5 nsec
Pixel Clock: 40.000 MHz, P= 25.0 nsec
9. External Reset Timing and Vertical Signals Timing
10. Async Reset Timing
External VD
Internal VD
FDV
Digital Data
Analog Video
VINIT Trigger
Internal VD
FDV
Digital Data
Analog Video
A [ 385 H], ( 12.5125 msec)
B [ <1 H], ( <32.5 µs)
C [ 9 H], (0.29 ms)
D [ 376 H], ( 12.22 ms)
E [ 385 H], ( 12.5125 ms)
F [ 0 H], ( 0.0 µs)
I [ 0 H], ( 0.0 µs)
L [ 3H], ( 97.5 µs)
P [ 3H], ( 97.5 µs)
G [ 135H], ( 4.3875 ms)
J [ 135H], ( 4.3875 ms)
M [ 132 H], ( 4.29 ms)
N [ 3H], ( 97.5 µs)
H [ 250 H], ( 8.125 ms)
K [ 250 H], ( 8.125 ms)
O [ 250 H], ( 8.125 ms)
S [ 376 H], ( 12.22 ms)
T [ 385 H], ( 12.5125 ms)
Y [ 250 H], ( 8.125 ms)
CC [ 250 H], ( 8.125 ms)
Q [VariableH], ( µs)
AA [ 132 H], ( 4.29 ms)
X [ 135 H], ( 4.3875 ms)
BB [ 3 H], ( 97.5 µs)
Z [ 3H], ( 97.5 µs)
R [ 9 H], ( 0.29 ms)
V [ 135 H], ( 4.3875 ms)
Q: Internal VD shift = 1H + async shutter speed
W [ 250 H], ( 8.125 ms)