Page 9
AccuPiXEL Series Camera Serial Commands
AccuPiXEL Series Camera-Control Software
TABLE 3.
Function Flag Description 1
SHTR2FLG (Bit3) -- 00 - (0) no shutter, 01 - (1) normal shutter
SHTR1FLG (Bit2) -- 10 - (2) direct shutter, 11- (3) async shutter
MSEL2FLG (Bit1) -- 00 - (0) normal scan, 01 - (1) partial scan #1 (optional)
MSEL1FLG (Bit0) -- 10 - (0) normal scan, #2 (optional), 11-(3) two-row scan
TABLE 4.
Function Flag Description 2
TSELFLG (Bit4) -- 0 - Select table A, 1 - Select table B
LUTB2FLG (Bit3) -- 00 - Linear mode; 01 - Knee mode (for table B)
LUTB1FLG (Bit2) --10 - Gamma mode; 11 - Direct input mode (reserved)
LUTA2FLG (Bit1) -- 00 - Linear mode; 01 - Knee mode (for table A)
LUTA1FLG (Bit0) -- 10 - Gamma mode; 11 - Direct input mode (reserved)
Byte 12 FUNCFLAG1 (1 byte) -- function flag #1
Byte 13 FUNCFLAG2 (1 byte) -- function flag #2
Byte 14 SHTRNUM (1 byte) -- current shutter number
Byte 15, 16 SHTRVAL (2 byte) -- manual/direct shutter value
BIT 7654 3210
FUNCFLAG #1 Resv Resv Resv Resv SHTR2FLG SHTR1FLG MSEL2FLG MSEL1FLG
BIT 7654 3210
FUNCFLAG #2 TSELFLG LUTB2FLG LUTB1FLG LUTA2FLG LUTA1FLG
TABLE 2.
16 Bytes Status Report (Continued)