TM-6760 Series Progressive Scan Shutter Cameras
Model: TM-6760 Operation Mode: Partial Centered 200L
120 Frames/Second
Master Clock: 50.0 MHz, M= 20 nsec
Pixel Clock: 25.0 MHz, P= 40 nsec
5. Partial Scan Timing
6. Partial Scan Async Reset Timing
External VD
Internal VD
FDV
Digital Data
Analog Video
VINIT Trigger
Internal VD
FDV
Digital Data
Analog Video
Horizontal Frequency: 31.48 KHz
1H = 31.76 µsec
A [ 262 H], (8.32 msec)
B [ <1 H], ( 31.76 µs)
C [9 H], ( 286 µs)
D [ 253 H], (8.04 ms)
E [ 262 H], ( 8.32ms)
F [ 0 H], ( 0 µs)
L [3 H], ( 95.3 µs)
P [ 3H], ( 95.3 µs)
G [ 62 H], (1.97 ms)
J [ 62 H], ( 1.97 ms)
M [ 59 H], ( 1.874 ms)
N [ 3H], ( 95.3 µs)
H [ 200 H], ( 6.35 ms)
K [ 200 H], ( 6.35 ms)
O [ 200 H], ( 6.35 ms)
S [ 253H], ( 8.04 ms)
T [ 262 H], ( 8.32 ms)
X [ 200 H], ( 6.35 ms)
BB [ 200 H], ( 6.35 ms)
U [ 0 H], ( 0 µs)
Z [ 59 H], ( 1.874 ms)
W[ 62H], ( 1.97 ms)
AA [ 3 H], ( 95.3 µs)
CC [ 3 H], ( 95.3 µs)
Y [3 H], ( 95.3 µs)
R [9H], ( 286 µs)
V [ 62 H], ( 1.97 ms)
Q: Internal VD shift = 1H + async shutter speed