INSTALLATION
Page 6 TM-6703 Progressive Scan Double Speed Shutter Camera
If wiring the PD-12 power supply directly, please note the following
•
Twist the lead ends together and tin solder for strength and electrical continuity
• Use shrink tubing or a similar insulator to prevent exposed leads from touching
• The +12V lead is marked with a red stripe or white lettering; be sure not to reverse the leads
• Properly insulate all connections to prevent shorting
2.2.3 (b) Using PULNiX Power/Video Cables
If you are using PULNiX power cables, such as the 12P-02, KC-10, etc., please refer to the pin-out
diagram. The color coded leads use Grey for Ground and Yellow for +12V DC.
FIGURE 2. 12P-02 Interface Cable (optional)
Note: Make sure that the unused leads are not touching and that there is no possibility that the
leads could short due to exposed wires.
2.2.3 (c) Using the “K” Series Power Supplies
Attach the 110V line cord to the two terminals marked “AC”. Do not plug the cord into a 110V AC
socket until later in the procedure. Next, attach the Grey and Yellow leads of the power cable to the
Ground and 12V DC terminals respectively. Be sure to replace the plastic terminal guard on the power
supply at this time.
12P-02 Interface Cable
Pin# Lead Color Function Pin# Lead Color Function
1 Gray GND 7 Black coax VD Input
2 Yellow +12VCD 8 White coax shield GND
3 Red coax shield GND 9 White coax HD Input
4 Red coax Video 10 Brown N/C
5 Orange coax shield GND 11 Blue Integration
6 Orange coax N/C 12 Black coax shield N/C
1
32mm
2,000mm± 10mm
(2 Meters)
PC-12P (Hirose Part #10A-10P-12S/PC12P)
Flying
Leads
1