OPERATION
TM-6703 Progressive Scan Double Speed Shutter Camera Page 17
3.2 Board Layout and Adjustment
3.2.1 Top Board (Top Side)
W5 AGC/MGC Left: AGC
Right: MGC
W6 Gamma Down: On (0.45)
Up: Off (1.0)
W7-W9 CDS pulse delay adjustment
VR1 AGC Set at 2.0V
VR2 MGC Controlled from
back plate
VR3 AGC MAX Set at 2.5V
VR4 PED Set at 50 mV of video
VR5 RG Factory adjustment only
VR7 Vsub Factory adjustment only
3.2.2 Bottom Board (Bottom Side)
VR2 PLL adjustment
W1 (VD), W2 (HD) HD and VD
input/output selection
VSUB
RG
PED
GAMMA
AGC
MAX
PLL
ASY
MAN