Pulnix TMC-6700 Series Manual de usuario Pagina 105

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 123
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 104
Kamerakabel
_______________________________________________________________________________________________________
INSPECTA hardware manual Rev 1.86 page 105
3 CH2+ 4
8 CH2- 12
5 CH3+ 5
10 CH3- 13
15 GND 8
11 VINIT+ 6
12 VINIT- 14
connector case cable shield connector case
7.30 Part # KKRDVISTEC**
plugs into B422A, B454, INSPECTA-4D Connector on SVS-Vistek camera
side
D62P-HD, male D-Sub 50P
Pin Nr.
D-62P HD
male
signal name Remark Pin Nr.
D-Sub 50P male
signal
name
23 PCLKA 29 STRB-
24 LDVA 46 LVAL-
25 FDVA 14 FVAL-
26 D8A 39 D8+
27 D9A 7 D9+
30 D0A 1 D0+
31 D1A 18 D1+
32 D2A 35 D2+
33 D3A 3 D3+
34 D4A 20 D4+
35 D5A 37 D5+
36 D6A 5 D6+
37 D7A 22 D7+
39 MC1 48 PRIN-
17 MC0 16 EXSYNC-
38 MC3 32 EXSYNC+
18 MC2 15 PRIN+
2 PCLKB 45 STRB+
3 LDVB 13 LVAL+
4 FDVB 30 FVAL+
5 D8B 23 D8-
6 D9B 40 D9-
9 D0B 34 D0-
10 D1B 2 D1-
11 D2B 19 D2-
12 D3B 36 D3-
13 D4B 4 D4-
14 D5B 21 D5-
15 D6B 38 D6-
16 D7B 6 D7-
21,42 GND 49,33 GND
shield/
connector-case
SHIELD
7.31 Part # KKRH**1300
The camera is connected to the Inspecta via one cable. There are two connectors
on the camera side, the Hirose 12-P and the 15P three row D-connector.