on --> async shutter disable, mode 0x31f
5: on, progressive scan, off dual channel
6: gamma correction
7: AGC
8: Manual gain
6.31 JAI CV-M10BX Rev. F
(Part # KKRH**M10F)
for JAI CV-M10BX Rev. F
camera mode Nr. of cameras
0xDFF 1 progressive
0xE0F 1 progressive, async. fixed or variable
shutter
Jumper 12/13 on PK8206 board (or PK8190 for RS version)inside camera must be
changed for fixed or variable shutter:
JP 12 JP 13
Open open Fixed shutter
Close close Variable shutter
Use driver software ≥ 3.01
Camera back-panel switches:
1: shutter speed ( see camera manual )
2: shutter speed ( see camera manual )
3: shutter speed ( see camera manual )
4: off --> async shutter enable
on --> async shutter disable, mode 0x31f
5: on, progressive scan, off dual channel
6: gamma correction
7: AGC
8: Manual gain
6.32 JAI CV-M30
( Part # KKRH**M30)
for JAI CV-M30 (CAMM30)
camera mode Nr. of cameras Async shutter
0x588 4 non interlaced, no shutter, one channel
Camera back-panel switches:
1: shutter speed ( see camera manual )
2: shutter speed ( see camera manual )
3: shutter speed ( see camera manual )
4,6: off, off: 100% scan, on, off: 50% scan, on, on: 33%scan
5: on: double speed
7: off: not external trigger
8: off: AGC off, on: AGC on
6.33 JAI CV-M40
(Part # KKRH**M40)
for CV-M40